Telecommunication Shelters

1. The Base Structure
TS is provided with a rigid base depending upon the shelter design requirements. Each base is designed to suit the shelter size and load requirements of the client; however the normal design is based on a minimum of a 1500kg m2 load. We can increase the load capacity, if required, by installing additional steel members to the base frame. The base structure consists of I beams which are supplemented by the use of hollow box tubes for the center support system All steelwork used on the base structure is cut and welded together before it is sent to galvanizing.

2. Panels
All TS’s consist of single insulated panels. Each of the insulated panels has an inner and outer skin which is made of Pre Painted galvanized steel with a thickness of 0.50 mm to 0.60mm depending upon the client’s requirements. Insulation is by way of Polyurethane foam which is machine injected between the skins (use 141B blowing agent) the total thickness of the completed panel is 100 mm. (we can produce panels to suit clients requirements).

 

Wall/Roof/Panels
Each panel manufactured has steel reinforced outer frame for extra support and strength of the panel and is used to join the wall/roof/floor panels together by arc welding or bolts. The panels are made to perfect fit together and ensure an air tight joint between each and every panel. The standard thickness is 100mm.

External Roof Panel (Optional)
The external roof panel has identical specs to the wall panels. It is placed on top of the roof panel and has a slight slant to insure no water gathering on top. It is a good ventilator for the shelter and is rigid enough to hold 200kg/m2. The standard thickness is 40mm.

Floor Panel
The floor panel is a steel reinforced structure with 18mm WBP plywood on the top end covered with 2mm antistatic tiles and 0.50mm galvanized steel sheet on the bottom end. The polyurethane foam is machine injected between the steel support frames inside the panel. The standard thickness of the floor panel is 100mm.

Door Panel
The door is constructed from insulated panel both the internal and external sides of the Door is of flat pre painted galvanized sheets 0.60 mm with machine injected Polyurethane for installation. Heavy duty door hinges provided, and a high quality of Locking system is installed complete with emergency opening system. Door dimension will be 1 m (W) x 2 m (H) the standard door thickness being 100mm

Jointing
Each joint on the shelter is sealed with a heavy duty anti fungus and vermin sealant. This is installed at the time of manufacturing. Our method of sealing the whole shelter ensures an excellent water and dust proof interior.
 

 

Shelter Construction

The TS’s are constructed from insulated panels combined with steel structures, which are specifically designed to offer complete protection from the climatic elements for the  equipment placed within the shelter. The thickness of the panels is normally 100mm,  however this can vary to suit our client’s requirements.

 

 
 